Respuesta :
Answer:
a) 0.72 V
b) 19.2 mA
c) 2.304 Watts
Explanation:
A transformer is used to step-up or step-down voltage and current. It uses the principle of electromagnetic induction. When the primary coil is greater than the secondary coil, the it is a step-down transformer, and when the primary coil is less than the secondary coil, the it is a step-up transformer.
number of primary turns = [tex]N_{p}[/tex] = 500 turns
input voltage = [tex]V_{p}[/tex] = 120 V
number of secondary turns = [tex]N_{s}[/tex] = 3 turns
output voltage = [tex]V_{s}[/tex] = ?
using the equation for a transformer
[tex]\frac{V_{s} }{V_{p} } = \frac{N_{s} }{N_{p} }[/tex]
substituting values, we have
[tex]\frac{V_{s} }{120 } = \frac{3 }{500} }[/tex]
[tex]500V_{p} = 120*3\\500V_{p} = 360[/tex]
[tex]V_{p}[/tex] = 360/500 = 0.72 V
b) by law of energy conservation,
[tex]I_{P}V_{p} = I_{s}V_{s}[/tex]
where
[tex]I_{p}[/tex] = input current = ?
[tex]I_{s}[/tex] = output voltage = 3.2 A
[tex]V_{s}[/tex] = output voltage = 0.72 V
[tex]V_{p}[/tex] = input voltage = 120 V
substituting values, we have
120[tex]I_{p}[/tex] = 3.2 x 0.72
120[tex]I_{p}[/tex] = 2.304
[tex]I_{p}[/tex] = 2.304/120 = 0.0192 A
= 19.2 mA
c) power input = [tex]I_{p} V_{p}[/tex]
==> 0.0192 x 120 = 2.304 Watts